GU36B
GU-36B-1

TETRODE

The GU-36B-1 power tetrode is used for wide-band power amplification at frequencies up to 250 MHz in stationary generalpurpose RF equipment.

GENERAL
Cathode: directly heated, carbonized thoriated tungsten.
Envelope: metal-ceramic with ring leads.
Cooling: forced air.
Height: at most 300 mm.
Diameter: at most 184 mm.
Mass: at most 11 kg.

gu-36b-1(1)1.jpg


OPERATING ENVIRONMENTAL CONDITIONS
Ambient temperature, °C -10 to +55
Relative humidity at up to + 25 °C, % 98
BASIC DATA
Electrical Parameters
Filament voltage (AC or DC), V 8.3
Filament current, A 110-130
Mutual conductance (at anode voltage 2 kV, grid 2 voltage 750 V, anode currents 4 and 6 A), mA/V, at least 70-96
Gain coefficient (at anode voltage 2 kV, grid 2 voltages 750 and 500 V, anode current 4 A) 7-13
Anode current (at anode voltage 2 kV, grid 2 voltage 9.000 V), A, at least 5
Negative cutoff voltage (at anode voltage 7 kV, grid 2 voltage 1.200 V, anode current 0.3 A), absolute value, V, at most 220
Interelectrode capacitance, pF:
input, at most 155
output, at most 24
transfer, at most 0.8
Output power (at frequencies up to 250 MHz, anode voltage at least 6 kV, grid 2 voltage 900 V bandwidth 8 MHz), kW, at least 10
Limit Operating Values
Filament voltage (AC or DC), V
at up to 50 MHz 8.3
at above 50 MHz 8.0
Filament starting current, A 210
Anode voltage (DC), kV:
at up to 100 MHz 8
at 100-250 MHz 7
Grid 2 voltage (DC), V 1,100
Negative grid 1 voltage (instantaneous value), absolute value, V 400
Dissipation, W:
anode 15x10³
grid 1 150
grid 2 300
Operating frequency, MHz 250
Temperature, °C
anode 250
stem and ceramic-to-metal seals 175

gu-36b-1(3)1.jpg
Averaged Anode-Grid Characteristic Curves:
Uf = 8.3V; Ug2 = 1.2kV

gu-36b-1(3)2.jpg
Averaged Grid 1 Characteristic Curves:
Uf = 8.3V; Ug2 = 1.2kV

gu-36b-1(3)3.jpg
Averaged Grid 2 Characteristic Curves:
Uf = 8.3V; Ug2 = 1.2kV
 
 




Numero accessi a questa pagina dal 02/2/00 - Totale[Count not available in text mode]